Fire protection to structural steel for main contractors, fit-out contractors and developers. Specified to your fire strategy, finished to the standard your client expects, and recorded for handover.
Fire ratings, set by your fire strategy
Protection and finish together
Planned with your programme
With a full O&M handover pack
Why project teams choose Vivid
An intumescent coating is a thin, paint-like fire protection for structural steel. In a fire it swells into an insulating layer that slows the rise in steel temperature, so the structure keeps its strength for the rating the building’s fire strategy requires, from 30 to 120 minutes. We make that package simple to buy.
We buy and manage the intumescent package: programme, access, thickness checks and records. Spraying and decorating sit in the same company, so you deal with one contractor.
Exposed steel is protected and finished to your specification on one programme: sheen, colour, sequence, and protection of finished steel from later trades.
Survey, access, containment and out-of-hours working agreed with your team before we start, so the steel is coated in sequence with the trades around us.
DFT records, QA documentation and photographs, including materials, batch and date information, in the O&M and handover package.
The standard we bring
Intumescent protection is one part of a finishing package. These are recent Vivid projects: decorating and spraying packages that show how we work with fit-out and construction teams, and the standard of finish we bring to every job.
A fast-track decoration overhaul of reception, the Orangery, brasserie and auditorium, delivered in six months with a swift turnaround.
A 15-month refurbishment of common areas and event spaces, phased around the hotel’s ongoing operations to minimise guest disruption.
A full decoration overhaul across three buildings, with distinct orange sprays to the spiral staircases that strengthen the brand’s identity.
Decoration to walls, ceilings and woodwork across four levels, with wallpaper to the ground floor corridor.
Where Vivid is different
Where steel is on show, the coating is part of the design. We plan the protection and the visible finish together, because the topcoat has to be approved for the system and must not stop the coating expanding in a fire.
A typical system: primer, intumescent basecoat, then a sealer or topcoat.
Where we work
We work as a specialist subcontractor for main contractors, fit-out contractors and developers on larger commercial projects in London and inside the M25.
Existing steel exposed by strip-out, and steel that stays visible in the finished space.
Floor-by-floor programmes, sequenced with the trades that follow. Penetrations through protected steel and walls are sealed as part of our fire stopping package.
Spraying planned around tenants, with containment and extraction, as at Senator House.
For cellular beams the coating must be a product tested and assessed for that beam type. The manufacturer calculates the thickness for each beam, and we apply to that schedule.
Ratings and systems
“
Exposed steel should look as good as the building around it: protected, finished and recorded.
The rating comes from the building’s fire strategy and Building Regulations guidance, not from us. We work to the rating, system and thickness schedule that the design team and the coating manufacturer set.
minutes
minutes
minutes, delivered at Senator House
minutes, some products
Thin film coatings are mainly used where the requirement is 30, 60 or 90 minutes, and some products now reach 120 minutes. We have experience working with Sherwin-Williams, Nullifire and Jotun systems. The coating system and loading are set by the manufacturer, based on the steel section sizes and the rating required.
Plain speaking
We tell you who does what, so you know who is on site and who is responsible for the work.
We buy the specified coating system and manage the package: programme, access, sequencing, thickness checks and records.
Specialist subcontract labour carries out the application. Most work is on site. Where it helps the programme, we have also applied primer at steel manufacturers’ premises, so it is compatible and correctly applied before the steel reaches site.
Our spraying and decorating business plans sheen, colour and sequence with the protection, so exposed steel is finished on the same programme.
How we work
Review and price
Send the steel schedule and fire strategy. We confirm the system, rating and thickness schedule for each element and price from them.
Survey and programme
Steel condition, existing coatings, access, containment and out-of-hours working agreed with the main contractor.
Apply, measure, correct
Specialist labour applies to the specified thickness. Dry film thickness is measured and recorded against the manufacturer’s schedule, and areas that fall short are corrected.
Seal, finish, hand over
A sealer or topcoat where specified, then the O&M and handover package.
Proof
A four-storey Victoria office building, stripped to bare shell with the steel blasted. The client needed 90 minutes of fire protection to existing and new steel across the basement, ground, first and second floors. We applied a Jotun intumescent system to the columns. The building still had tenants, so the spraying was carried out out of hours, and we had windows removed to install local exhaust ventilation.
Fire protection work by Vivid Finishes
Compliance, handled
Thickness decides the fire rating, so it is measured. Dry film thickness is recorded against the manufacturer’s thickness schedule for each steel element, set from tested data for the section, the rating and the steel’s limiting temperature. Areas that fall short are corrected, and the records go in the O&M and handover package.
Regulation 38 of the Building Regulations requires fire safety information to be passed to the responsible person when work completes. Technical background: the Steel Construction Institute guide to fire protecting structural steelwork.
Third-party certification requirements differ by project and package. If your specification asks for a particular scheme for coatings application, tell us at the start and we will confirm what we can provide for that package before you commit.
See our accreditations, health and safety approach and environmental commitments.
Straight answers
An intumescent coating, often called intumescent paint, is a thin fire protection applied to structural steel. It stays inert until a fire heats it to around 200 to 250°C, then swells into an insulating char layer. That layer slows the rise in steel temperature so the structure keeps its strength for the rated time.
Thin film intumescent coatings are mainly used for 30, 60 and 90 minute requirements, and some products now reach 120 minutes. The rating that applies comes from the building’s fire strategy. We work to the rating, system and thickness schedule that the design team and the coating manufacturer set.
It depends on the steel. The manufacturer’s tested data gives the dry film thickness for each section, based on its section factor (heated perimeter divided by cross-sectional area), the rating required and the steel’s limiting temperature. Slender sections need more coating than heavy ones. Thickness runs from a fraction of a millimetre to a few millimetres.
Yes, with a topcoat the manufacturer approves for that system. Some systems need no topcoat in a dry, controlled internal environment, and the data sheet says which. Exact colour matches with standard paint can be difficult, so agree the finish and a sample area early. Our spraying and decorating business plans the finish with the protection.
We buy the coating, manage the package and arrange the application, which is carried out by specialist subcontract labour. We say this plainly so you know who is on site and who is responsible for the work. Our spraying and decorating business plans the finish with the protection.
Yes. At Senator House in Victoria, the building still had tenants, so we carried out the spraying out of hours and installed local exhaust ventilation through removed windows. We plan access, containment and programme with the main contractor before work starts.
Yes. We work as a specialist subcontractor for main contractors, fit-out contractors and developers on larger commercial projects, including Cat A and Cat B office fit-out and refurbishment. Tell us the size, location and programme and we will confirm availability.
Send us the steel schedule or drawings (member sizes, lengths and quantities), the fire rating for each element, whether the steel is blasted, primed or already coated, whether it will be exposed or concealed, the site location and access, and your programme. Our lines are open 9 to 5, Monday to Friday.
It depends on the project, so we price from your steel schedule. The main factors are the rating, the section factors and quantity of steel, the number of coats, whether a finish is specified, access and out-of-hours working. Higher ratings and slender sections need more material and more coats, so they cost more.
Discuss your project
We price from the steel. Send what you have and we will come back to you. Include:
Our lines are open 9 to 5, Monday to Friday. For main contractors, fit-out contractors and developers. See about Vivid Finishes.
Keep exploring
Fire stopping, fire barriers and acoustic sealing, delivered as one package.
Also see all our finishes, curtain wall spraying and the fire protection overview.